Calibration System and Algorithm Design for a Soft Hinged Micro Scanning Mirror with a Triaxial Hall Effect Sensor
Di Wang, Xiaoyu Duan, Shu-Hao Yeh, Jun Zou, Dezhen Song
Abstract
Micro scanning mirrors (MSMs) extend the range and field of view of LiDARs, medical imaging devices, and laser projectors. However, a new class of soft-hinged MSMs contains out-of-plane translation in addition to the 2 ◦-of-freedom rotations, which presents a cabliration challenge. We report a new calibra- tion system and algorithm design to address the challenge. In the calibration system, a new low-cost calibration rig design employs a minimal 2-laser beam approach. The new new algorithm builds on the reflection principle and an optimization approach to pre- cisely measure MSM poses. To establish the mapping between Hall sensor readings and MSM poses, we propose a self-synchronizing periodicity-based model fitting calibration approach. We achieve an MSM poses estimation accuracy of 0.020◦with a standard deviation of 0.011◦.